ISDN-Tester INTEC Argus 10 for certifieng ISDN Installations
Article number: 34611
Listed in category: Measurement / Wire and Cables > ISDN-Tester INTEC Argus 10 for certifieng ISDN Installations
from brakensiek.de
from brakensiek.de
ISDN tester Argus 10
Non-new
Including:
Power Supply
Manual
Connection cable
ARGUS ® 10 -
The universal Uk0 S0-a / b tester at a glance
* Ergonomic design with integrated receiver
* S0 interfaces in TE / NT operation including D-channel monitoring
* Uk0 and analog interface in the TE mode
* Clip and fees to analog
* Test wiring for the S0-bus
* Spannunge and signal level measurement
* Intuitive menu navigation
* Operating with cursor keys, soft keys and direct-mode keys
* Automation shear test sequence (Autotest) with storage
* Data transfer to PC
* Power supply from S0, battery, battery or AC adapter
* Flash-ROM technology for software updates via PC
ARGUS ® 10 - The functions on the S0 bus
* S0-a CCITT I.420 - Modes of operation:
TE (terminal simulation), NT (network simulation), monitor
(Passive intrusion on S0 bus with online data recording on PC)
* Automatic detection of protocol and port configuration:
Point-to-point or point-to-multipoint, DSS1, 1TR6, BILINGUAL or NO protocol
Display of Layer 1-2-3 and B-channel status (free / busy)
* In addition CorNet CorNet-N and T can be selected
* Automatic Service Test: determines which ISDN services to send and receive side
available at the terminal are
* Automatic detection of service features
- With 1TR6: DM-query;
- For DSS1: automatic. Tests of CLIP, CLIR, COLP, COLR, HOLD, TP, CFU, CFB, CFNR,
Fees A / B (AOC-D / E), CCBS, calls on no reply (CCNR), ECT, 3pty, displaying
Subaddress SUB, UUS User text for incoming calls and keypad protocol is supported
* Bus status query with a query, view and delete the
active call diversions CFU, CFB, CFNR for all services
* Automatic X.31 (D) test: Is the service feature "Packet data in D-channel"
available and what the TEI values are assigned to the terminal,
Simulation of X.31 (D) terminal to X.25 network
* Telephone functions with hot-button phone, phone number memory for 10 numbers
or keypad protocol commands that display the calling and called number on incoming calls,
B channel, block, or individual choice
* Use of 2 simultaneous calls at call with self acceptance and loopbox
* Terminal or network simulation for different ISDN services
* Display of the main reasons for termination and the release site in plain text
* Share of fees, date and time in the NT simulation
* BERT bit error test with evaluation according to the G.821 extended self-call
and end-end distance BERT, display of bit errors and bit error rate, One dear of bit errors,
BERT with adjustable Gut-/Schlecht-Schwelle and OK / Not OK evaluation
Pattern acc. ITU-T O.150, adjustable measuring time, loop box function for B-channels and all services
* Tests of ISDN leased lines: Telephone function and BERT
B channel B1 or B2 selectable loop box function for B-channels
* Layer 1 tests and bus-powered: Measurement and evaluation of the phantom
(OK, NORMAL or Restricted Power)
and the ISDN signal transmission and reception level of the NTBA or PBX
* Display of Layer 1 Info S0-S4
* Cabling Tests: Testing of the bus termination resistors,
There is a short circuit or an Adernvertauschung?
If so, which wires? View as plain text
ARGUS ® 10 - The Uk0 and a / b-functions
* Interface with Uk0 4B3T or 2B1Q
* Measurement of voltage incl Uk0 OK evaluation, Uk0 TE functions such as S0
* Stress test with variable load to determine the quality management
* A / b interface with DTMF and pulse dialing with flash function
(80, 120, 240 and 600 ms), loop resistance: 470 ohms
* Voltage measurements on a / b (on-hook and off-hook) with polarity indicator
* Telephony functions for a / b as S0-Call number (CLIP)
* Display of fees by 12 and 16 kHz pulse
* A / b monitor with CLIP, DTMF, display fees and listening
ARGUS ® 10 - Hardware
* Power Supply: alternatively supplied from ISDN S0
Standard batteries (3 x 1.5 V AA) batteries or AC adapter
* Keypad: 16 keys, 2 cursor buttons, 3 soft keys
* LCD display: 4 lines with 16 characters, backlit
* 5 LEDs to indicate status (ISDN Layers 1 - 2 - 3, PC Trace, power supply)
* Size: H 230mm W 72mm D 30mm
* Weight: 350 grams (without batteries)
Non-new
Including:
Power Supply
Manual
Connection cable
ARGUS ® 10 -
The universal Uk0 S0-a / b tester at a glance
* Ergonomic design with integrated receiver
* S0 interfaces in TE / NT operation including D-channel monitoring
* Uk0 and analog interface in the TE mode
* Clip and fees to analog
* Test wiring for the S0-bus
* Spannunge and signal level measurement
* Intuitive menu navigation
* Operating with cursor keys, soft keys and direct-mode keys
* Automation shear test sequence (Autotest) with storage
* Data transfer to PC
* Power supply from S0, battery, battery or AC adapter
* Flash-ROM technology for software updates via PC
ARGUS ® 10 - The functions on the S0 bus
* S0-a CCITT I.420 - Modes of operation:
TE (terminal simulation), NT (network simulation), monitor
(Passive intrusion on S0 bus with online data recording on PC)
* Automatic detection of protocol and port configuration:
Point-to-point or point-to-multipoint, DSS1, 1TR6, BILINGUAL or NO protocol
Display of Layer 1-2-3 and B-channel status (free / busy)
* In addition CorNet CorNet-N and T can be selected
* Automatic Service Test: determines which ISDN services to send and receive side
available at the terminal are
* Automatic detection of service features
- With 1TR6: DM-query;
- For DSS1: automatic. Tests of CLIP, CLIR, COLP, COLR, HOLD, TP, CFU, CFB, CFNR,
Fees A / B (AOC-D / E), CCBS, calls on no reply (CCNR), ECT, 3pty, displaying
Subaddress SUB, UUS User text for incoming calls and keypad protocol is supported
* Bus status query with a query, view and delete the
active call diversions CFU, CFB, CFNR for all services
* Automatic X.31 (D) test: Is the service feature "Packet data in D-channel"
available and what the TEI values are assigned to the terminal,
Simulation of X.31 (D) terminal to X.25 network
* Telephone functions with hot-button phone, phone number memory for 10 numbers
or keypad protocol commands that display the calling and called number on incoming calls,
B channel, block, or individual choice
* Use of 2 simultaneous calls at call with self acceptance and loopbox
* Terminal or network simulation for different ISDN services
* Display of the main reasons for termination and the release site in plain text
* Share of fees, date and time in the NT simulation
* BERT bit error test with evaluation according to the G.821 extended self-call
and end-end distance BERT, display of bit errors and bit error rate, One dear of bit errors,
BERT with adjustable Gut-/Schlecht-Schwelle and OK / Not OK evaluation
Pattern acc. ITU-T O.150, adjustable measuring time, loop box function for B-channels and all services
* Tests of ISDN leased lines: Telephone function and BERT
B channel B1 or B2 selectable loop box function for B-channels
* Layer 1 tests and bus-powered: Measurement and evaluation of the phantom
(OK, NORMAL or Restricted Power)
and the ISDN signal transmission and reception level of the NTBA or PBX
* Display of Layer 1 Info S0-S4
* Cabling Tests: Testing of the bus termination resistors,
There is a short circuit or an Adernvertauschung?
If so, which wires? View as plain text
ARGUS ® 10 - The Uk0 and a / b-functions
* Interface with Uk0 4B3T or 2B1Q
* Measurement of voltage incl Uk0 OK evaluation, Uk0 TE functions such as S0
* Stress test with variable load to determine the quality management
* A / b interface with DTMF and pulse dialing with flash function
(80, 120, 240 and 600 ms), loop resistance: 470 ohms
* Voltage measurements on a / b (on-hook and off-hook) with polarity indicator
* Telephony functions for a / b as S0-Call number (CLIP)
* Display of fees by 12 and 16 kHz pulse
* A / b monitor with CLIP, DTMF, display fees and listening
ARGUS ® 10 - Hardware
* Power Supply: alternatively supplied from ISDN S0
Standard batteries (3 x 1.5 V AA) batteries or AC adapter
* Keypad: 16 keys, 2 cursor buttons, 3 soft keys
* LCD display: 4 lines with 16 characters, backlit
* 5 LEDs to indicate status (ISDN Layers 1 - 2 - 3, PC Trace, power supply)
* Size: H 230mm W 72mm D 30mm
* Weight: 350 grams (without batteries)
Contact:
Your contact person: Tim Brakensiek
purchase list
last update:
21.11.2012